UPVC Window Profile Series 50–112: Technical Selection Parameters
A window schedule that lists UPVC profile series 50, 60, 65, 80, 88 and 112 is giving you a production range, not a performance ranking. The series number identifies the profile designation; what decides whether a window survives a coastal high-humidity façade or an occupied-building renovation is documented wind-pressure resistance, water tightness, air permeability, UV and anti-aging performance, optional fire resistance and hardware compatibility for manual operation.
Foshan Nanhai Yuanzhaiji UPVC Door & Window Factory holds an ECM Attestation whose scope names all six series, which settles coverage — not the class rating of any individual window build. This guide is written for buyers in the evaluation-to-execution stage: you have a shortlist or a purchase order forming, and you need the parameters to write into the specification, the documents to request, and a clear view of how two reference configurations fit the decision. Product 8037 is used here as the strong-wind, coastal example; product 7970 as the renovation and commercial example.
The specification problem: a series number is not a performance rating
Two different questions get mixed together in most profile catalogues. The first is scope: which profile series a factory can produce and attest. The second is performance: what one specific window — at one specific size, with one specific glass build and hardware set — achieves under wind load, rain and pressure difference. A scope statement answers the first question completely and the second one not at all, and procurement documents that treat them as the same question usually end up with a certificate nobody can map to a delivered unit.
Series numbering follows a naming convention rather than a rule book. In UPVC window systems the number conventionally corresponds to the nominal profile depth in millimetres, so a 60 series profile is nominally deeper than a 50 series profile, and 112 is the deepest in this range. Depth creates room for chambers, reinforcement and glazing, but the assembled window's behaviour comes from how those parts are combined during fabrication and installation. Treat the series number as a reading aid on the drawing, and confirm actual profile dimensions, wall thickness and chamber layout with the supplier in writing.
The second half of the problem is evidence asymmetry. Profile quality varies widely between producers, and the same nominal series can be manufactured to different wall-thickness and additive standards. The reference standard in this supplier's technical material is GB/T 8814-2017 for unplasticized PVC-U profiles for doors and windows, which sets requirements on wall thickness, impact resistance, heat stability and anti-aging performance, with qualified test reports expected as verification. A series list without those reports is a starting point, not a selection.
Where this series range sits in the current supply picture
Published research puts the global uPVC windows and doors market at USD 30.8 billion in 2025 (Grand View Research), with Asia Pacific holding a 44.1% revenue share; windows account for 58.0% of product revenue, and casement windows and doors hold the largest design-type share at 38.5% (Dataintelo). Sizing estimates differ by methodology — Mordor Intelligence values the same 2025 market at USD 42.15 billion — so read these figures as a description of how supply is structured, not as a benchmark for a single supplier's price.
Manufacturing concentration matters more to a buyer than the headline number. Foshan Nanhai is a key manufacturing base for UPVC profiles and windows, and an industry publication estimates the service life of high-quality profiles from that cluster at 30 to 40 years. The estimate applies to the profile under normal exposure with competent fabrication and installation; it is not a warranty on a finished window, and it does not transfer automatically to an under-specified profile bought on price.
Concrete supply facts help here. This factory's stated long-term profile supply covers Conch 60, 65 and 88 series in co-extruded colour, laminated wood-grain finish and solid colours such as dark grey and black. Separately, the ECM Attestation names series 50, 60, 65, 80, 88 and 112 as covered profile series. Those are two different statements — one about a branded profile channel with defined colour options, the other about certified scope — and a good specification keeps them distinct.
Mapping the ECM Attestation to profiles 50, 60, 65, 80, 88 and 112
The attestation record is short, and every line carries weight for a buyer:
- Certificate: ECM Attestation NO.3N230816.YCPQQ51, a voluntary certification
- Authority: Ente Certificazione Macchine Srl (ECM)
- Scope: UPVC Windows and Doors, Profiles Series 50/60/65/80/88/112
- Standard: EN 14351-1:2006+A2:2016
- Validity: issued 16 August 2023, expiry 15 August 2028
- Market designation: intended for third countries outside the EU market
Read the scope line first. "Profiles Series: 50/60/65/80/88/112" is what makes the document relevant to this article's range: it confirms that all six series sit inside the attested factory scope, so a project specifying any of them is not stepping outside the certification. That is a real procurement advantage when a façade package mixes series across unit types, because one scope document covers the whole schedule.
Read the market line second. The record states the attestation is intended for third countries outside the EU market. For a project destined for the EU, ask the supplier which document set supports that specific route rather than assuming this attestation carries it. This is a scope reading, not a legal opinion, and it is the single most common place where buyers misread a certification.
Read the standard line third, and do not over-read it. The record names EN 14351-1:2006+A2:2016. It does not, on its own, publish wind-load, water-tightness or air-permeability classes for each series and each window size. Those values belong to the test report for the configuration you are buying. The difference matters: "series 88 is inside the certified scope" is a statement about the factory, while "a 2.4 m by 1.5 m casement in series 88 reaches class X at your design wind pressure" is a statement about a unit, and only the test report can make it.
Read the dates last. An issue date of 16 August 2023 and an expiry date of 15 August 2028 give a working verification window. On a multi-year building programme, re-check validity at purchase order and again before final shipment, and keep a copy of the certificate version you relied on in the project file.
The same record links two products to the scope: product 8037 (models BR58, HF88) and product 7970 (models HF60, WYK75-1, HF88-L). That linkage is useful during evaluation because it shows which reference units the supplier associates with the attested scope — but it still does not replace configuration-level test data.
Six technical parameters to write into the specification
1. Wind-pressure resistance and water tightness on coastal high-humidity projects
Wind-pressure resistance describes how a window resists deflection and structural failure under gust load; water tightness describes how it resists rain penetration at a stated pressure difference. On a coastal high-humidity site the two are physically linked, because wind-driven rain reaches the same joint that is deflecting. Neither value should be taken from a catalogue default: design wind pressure comes from the project's structural engineer, based on height, exposure and terrain, and the window is then specified against that number.
What to request is a test report for the exact configuration — same series, same opening type, comparable sash dimensions — plus the frame and sash reinforcement detail and the sealing and drainage detail. On sliding and casement units the sealing path runs through components that are easy to under-specify. EPDM sealing gaskets carry the compression seal; pile weather strips close the sliding or opening gap. Both appear in this supplier's window-application hardware list and both belong in the hardware schedule rather than in a line reading "standard sealing".
Product 8037 is the strong-wind and coastal reference in this guide, with window rollers, EPDM sealing gaskets and pile weather strips forming the movement and sealing set. Three checks before approval: match the roller specification to sash weight and glass build, confirm the gasket and weather strip run continuously through corners and hardware cut-outs, and confirm the drainage path discharges away from the wall below.
2. Air permeability: the parameter that decides draughts, dust and noise
Air permeability measures leakage through a closed window at a stated pressure difference. It is the parameter most often skipped in warm-climate procurement because it never fails visibly, yet it drives draughts, dust ingress, condensation risk at the frame and the practical acoustic result. Specifying a window for a humid coastal building without an air-permeability target is specifying the frame and hoping for the seal.
Certified classes tell you the test result; the mechanism tells you what to inspect. Air tightness on a manually operated window depends on gasket compression along a continuous line, on lock points that pull the sash in evenly, and on the absence of gaps at corners and hardware cut-outs. For casement and tilt-and-turn units, ask how many lock points the sash carries and how the gasket is spliced. For sliding units, ask about the seal at the interlock and whether the track is drained and vented.
Acoustic performance should be evaluated in the same pass, because it depends on the same sealing line and on the glass build. The supplier's project record for an 800 m² builders' project in Kenya lists heat-insulation and sound-insulation performance and energy saving among outcomes, with low-noise sliding, water-proofing, dust-proofing and easy maintenance listed as highlights. Read that as a documented project description, then ask for the acoustic data attached to the glazing build you actually intend to order.
3. UV resistance and anti-aging for outdoor exposure
UPVC is polyvinyl chloride with stabilisers and additives, not a naturally weather-proof material. UV radiation triggers molecular-chain degradation in PVC; qualified profiles add UV stabilisers to resist it, and wall thickness provides the structural margin against thermal deformation. Thin walls and a weak additive package surface later as yellowing, brittleness, deformation and air leakage — the failure mode this supplier's own technical guidance attributes to under-specified mid-range profiles and to counterfeit branded profiles.
Verification here is documentary rather than visual. Request the profile test report against GB/T 8814-2017 covering wall thickness, impact resistance, heat stability and anti-aging performance. Confirm the profile source in writing, and where a branded profile such as Conch is specified, confirm the genuine supply channel instead of accepting a trade name typed onto a quotation. Where a colour or finish is specified — co-extruded colour, laminated wood-grain or a solid colour such as dark grey or black — ask for the weathering evidence that applies to that finish, not only to the natural white profile.
Coastal humidity adds a second, separate exposure: salt-laden air attacks hardware rather than the PVC-U itself. PVC-U is chosen for these projects for corrosion resistance, water-tight sealing, low maintenance and easy cleaning, but hinges, rollers, handles and lock mechanisms decide whether the window still operates smoothly in year eight. Specify hardware base material and finish with the same care as the profile.
4. Optional fire resistance: specify it or leave it out, but never assume it
Fire resistance appears in this supplier's window application data as an optional special requirement, listed alongside wind-pressure resistance, water tightness, air permeability, sound and heat insulation and UV/anti-aging performance. It is not a property that arrives with the series number, and it should never be inferred from the standard reference printed on a product attestation.
If the building code for your project requires a fire classification, state the required classification, the test standard and the assessment route in the specification, then request the classification report for the complete window assembly including glazing and hardware. The practical consequence is a split schedule: units on the fire-rated line are specified, tested and approved separately from standard units, even where both use profiles from the same series. Combining them on one approval document is how a project ends up holding a certificate that cannot be mapped to a delivered window.
5. Manual operation and hardware compatibility
Every opening type in this range is manually operated: sliding, casement, tilt-and-turn, crank awning, American-style hung, awning, hopper and louver units, with manual opening and closing, tilt-and-turn and sliding operation modes. Manual operation sounds trivial until it is tested on a deep sash at a coastal site, where a stiff handle or a two-handed lock turns into a maintenance call.
Three checks reduce that risk. First, the lock-point count and drive mechanism: a single-point latch and a multipoint drive behave differently under wind load and under attempted forced entry. Second, the hinge or roller rating against sash weight and glass build, since a heavier glazing package changes the load path. Third, handle height and operating force against the people who will actually use the window, including children and older occupants in residential projects.
Product 7970 is the renovation and commercial reference here, associated with a multipoint lock drive mechanism and a crescent lock in its manual hardware set. Both are compatibility questions rather than marketing points: a multipoint drive needs frame and sash prepared for the same lock-point positions, and a crescent lock must match the sash stile width and the ventilation position the design intends. On a renovation, add the existing opening to the check, because out-of-square reveals and uneven sills change how the frame is packed — and no hardware schedule performs inside a frame installed twisted.
6. Thermal and glazing parameters that carry the specification
Thermal performance is specified as a whole-window U-value and verified by calculation or test for the configuration, never by a profile claim. As an external reference point, the legal whole-window U-value limit for window replacement in existing homes in England and Wales is 1.4 W/m²K in 2025 under Approved Document L. Other markets set their own limits, so the target value should come from the project's authority rather than from a supplier catalogue.
Glazing options for the range include single-layer glass, double-glazed insulated glass, tempered safety glass and frosted glass, and custom glass specification is available on window and door orders. Each choice moves the U-value, the weight carried by hinges or rollers and the acoustic result, which is why the glass build belongs in the same approval document as the profile series. An enquiry for a double or triple glazed UPVC window should come back with a calculated whole-window value for the actual size, not a generic glazing description.
Selection parameters at a glance
| Parameter | What it governs | Document to request | Priority rises when |
|---|---|---|---|
| Wind-pressure resistance | Deflection and structural safety of frame and sash under gust load | Test report for the same series, opening type and comparable sash size | Coastal, high-rise or exposed sites |
| Water tightness | Resistance to rain penetration at a stated pressure difference | Test report plus sealing, gasket and drainage detail | Driving-rain exposure, high humidity |
| Air permeability | Draughts, dust ingress, condensation risk and acoustic result | Test report plus lock-point and gasket schedule | High wind, acoustic targets, energy targets |
| UV resistance and anti-aging | Yellowing, embrittlement, deformation over service life | Profile test report to GB/T 8814-2017; finish-specific weathering evidence | Long outdoor exposure, dark colours |
| Thermal transmittance | Whole-window U-value against a code or client target | Calculation or test for the actual size and glass build | Regulated markets, energy-driven projects |
| Fire resistance (optional) | Fire classification of the complete assembly | Classification report for assembly, glazing and hardware | Code requires a fire-rated line |
| Hardware compatibility | Manual operation, security and serviceability | Hardware schedule with lock type, roller or hinge rating, spare parts | Renovation, commercial, high-use units |
A document-based selection workflow
- Fix the project conditions before the series. Record exposure (coastal, high-rise or sheltered), design wind pressure from the structural engineer, driving-rain exposure, humidity, acoustic target, code requirements and whether a fire-rated line is required. This list, not the catalogue, decides which series is even eligible.
- Convert conditions into a performance schedule. Write target values or classes for wind-pressure resistance, water tightness, air permeability and U-value, and a fire classification where applicable, with each unit's size and opening type attached.
- Map series to units, not to the project. Assign each unit a series and record the nominal profile depth from the supplier's drawing, wall thickness, chamber layout and reinforcement. Series 112 on a small bathroom window and series 50 on a full-height slider are both decisions that need a stated reason.
- Request the full document set once. The ECM Attestation (NO.3N230816.YCPQQ51, valid to 15 August 2028), configuration-level wind, water and air test reports, the GB/T 8814-2017 profile test report, glass certificates and, where required, the fire classification report for the complete assembly.
- Check the hardware schedule against the operation mode. For 8037 that is the roller, EPDM gasket and pile weather strip set; for 7970 it is the multipoint lock drive mechanism and crescent lock. Confirm that replacement parts will be identifiable after handover.
- Resolve commercial parameters against the same schedule. Minimum order 30–40 m², typical production lead time 10–30 days, FOB or CIF terms, bank transfer payment, and acceptance by pre-shipment photo inspection or on-site inspection.
- Approve a first article. Inspect the first completed unit against the approved drawing — profile dimensions, gasket continuity, lock operation, glazing build — before the balance of the order is released.
Two reference configurations: 8037 for strong-wind coastal, 7970 for renovation and commercial
Both products sit inside the ECM scope, so choosing between them is a project-fit question rather than a compliance question. The difference lies in which failure path each configuration is built to control.
8037 is the strong-wind, coastal reference. Its hardware emphasis — window rollers, EPDM sealing gaskets and pile weather strips — points at the two paths that matter in salt air and driving rain: sash movement under gust load and water penetration at the opening joint. Verify the roller set against sash weight and glass build, confirm gasket compression is continuous through corners, and confirm the drainage detail on the drawing.
7970 is the renovation and commercial reference, associated with a multipoint lock drive mechanism and a crescent lock. That makes it the configuration to examine where security, ventilation control and repeatable operation across many identical units matter more than coastal wind exposure: commercial elevations, residential refurbishment that keeps existing opening sizes, and projects where one hardware standard must serve hundreds of windows.
| Selection item | Product 8037 (strong-wind / coastal) | Product 7970 (renovation / commercial) |
|---|---|---|
| Reference role in this guide | Coastal high-humidity and strong-wind projects | Renovation and commercial projects |
| Hardware set to verify | Window rollers, EPDM sealing gaskets, pile weather strips | Multipoint lock drive mechanism, crescent lock |
| Operation checks | Roller rating versus sash weight; seal continuity at corners | Lock-point positions versus frame preparation; ventilation position |
| ECM coverage | Inside the attested profile range 50/60/65/80/88/112 | Inside the attested profile range 50/60/65/80/88/112 |
| Still to confirm in writing | Wind, water and air test report for the actual unit size | Hardware schedule for the actual opening and existing reveal |
Use cases: which parameter moves when the project changes
Coastal high-humidity residential. Wind-pressure resistance and water tightness lead, with hardware corrosion immediately behind them. Use 8037 as the reference configuration, request the test report at the project's design wind pressure, and put the hardware finish into the specification rather than into a verbal agreement.
Commercial building renovation. Operation and consistency lead. Use 7970 as the reference, measure the existing openings before ordering, and confirm that the multipoint lock and crescent lock preparation matches the stile geometry. Phased delivery suits the 10–30 day typical lead time, and the 30–40 m² minimum order allows a first-phase trial before the full elevation is released.
Villa and large-aperture residential. Sash weight leads, because it drives the roller or hinge choice and the operating force. A heavier double or triple glazed build changes that calculation, so approve the glazing specification before the hardware schedule is frozen.
OEM and distributor programmes. Repeatability leads. The factory provides OEM, ODM and customizable production with customization of window size, specification and glass specification, at 4,000 m² monthly capacity. Freeze the hardware schedule and the profile series for the whole run, because a mid-programme substitution is what makes spare-part support impossible two years later.
Frequently asked questions
Which profile series does the ECM Attestation cover, and what does it not certify?
The attestation (NO.3N230816.YCPQQ51, issued by Ente Certificazione Macchine Srl) names UPVC Windows and Doors with profiles series 50/60/65/80/88/112 in its scope, under EN 14351-1:2006+A2:2016, issued 16 August 2023 and valid to 15 August 2028, with a market designation of third countries outside the EU. It confirms that all six series fall inside the attested factory scope. It does not state wind-load, water-tightness or air-permeability classes for each series and size, and it does not state a fire classification; those must come from configuration-level test reports.
Which China OEM UPVC window manufacturers can support custom residential projects?
For this reference supplier, OEM, ODM and customizable production of UPVC windows and doors is available, with customization of window size, specification and glass specification. Production capability covers UPVC sliding windows, casement windows and casement doors, at a monthly capacity of 4,000 m² with a typical lead time of 10–30 days. Qualify any manufacturer — in China or elsewhere — on documents rather than on the country of origin: certified scope, configuration-level test reports, profile test reports to GB/T 8814-2017, and a documented hardware schedule.
Can product 7970 be specified with both a multipoint lock and a crescent lock?
7970 is associated with a multipoint lock drive mechanism and a crescent lock, and the two do different jobs. The multipoint drive distributes lock points along the sash and needs matching frame preparation; the crescent lock is a single-point latch that secures the sash closed or at a limited opening position for ventilation. Specify both only where the shop drawing shows preparation for each, and confirm the arrangement on a sample unit before the order is released.
What is the minimum order quantity for a custom residential window package?
Orders are accepted from a minimum of 30–40 m², and the same 30–40 m² requirement applies to custom UPVC window orders. That threshold is workable for a single-house package or a first-phase trial on a larger project, which is why the selection workflow recommends approving one unit before releasing the balance.
How can windows be verified before shipment?
Two acceptance routes are available: pre-shipment inspection via photographs before dispatch, or on-site inspection as part of the acceptance process. Payment is by bank transfer, with FOB or CIF delivery terms. A sample showroom is also maintained for one-stop purchasing checks, which is useful when a colour, finish or hardware combination has to be confirmed physically rather than from a data sheet.
How long does production take once a window schedule is approved?
The typical production lead time is 10 to 30 days, against a monthly capacity of 4,000 m². Plan the purchase order around first-article approval rather than around the shipment date, and re-check the certificate validity period on long programmes. To request a sample unit or a formal quotation for a specific series, size and glass build, submit the schedule through yuanzhaiji.com so the quotation and the test-report request are answered against the same specification.
Conclusion
Series 50 through 112 give a buyer range and flexibility; they do not give a performance classification. The ECM Attestation settles the scope question by naming all six series under EN 14351-1:2006+A2:2016, with a validity running to 15 August 2028 and a stated market designation of third countries outside the EU. Everything that determines whether a window performs — wind-pressure resistance, water tightness, air permeability, UV and anti-aging evidence, optional fire classification and hardware compatibility — has to be verified at configuration level, in writing, before approval.
Used well, the range becomes a decision tool: 8037 as the strong-wind coastal reference with its roller, EPDM gasket and pile weather strip set, and 7970 as the renovation and commercial reference with multipoint lock and crescent lock hardware. Match the series and hardware to the project conditions, request the documents that prove the claim, and approve a first article. That sequence is what converts a profile list into a window specification.
Have Questions or Need More Details?
Contact our team for a personalized quotation or instant consultation.
Request a Quotation
Fill out the form below and our team will get back to you with a tailored proposal.
WhatsApp Direct Chat
Prefer to chat in real-time? Message us on WhatsApp for instant assistance & quick answers.
- Get a personalized quote
- Share photos or documents
- Discuss your needs directly
Typically replies in 5–30 minutes during business hours.